/ Accelerators


Studying the counting rate capability of a glass multigap resistive plate chamber at an increased operating temperature


Gapienko, V.A. (Serpukhov, IHEP) ; Gavrishchuk, O.P. (Dubna, JINR) ; Golovin, A.A. (Serpukhov, IHEP) ; Semak, A.A. (Serpukhov, IHEP) ; Sychkov, S.Ya. (Dubna, JINR) ; Sviridov, Yu.M. (Serpukhov, IHEP) ; Usenko, E.A. (Dubna, JINR) ; Ukhanov, M.N. (Serpukhov, IHEP)

Published in: Instrum.Exp.Tech. / Prib.Tekh.Eksp.
Year: 2013 / 2013
Vol.: 56 / 2013    Num./Issue: 3
Page No: 265-270 / 21-26
Pages: 6

Abstract: It is shown that a multigap resistive plate chamber made of commercial float glass is capable of sustaining high counting rates at an increased operating temperature. Two glass chambers were investigated on the test beamline of the U-70 accelerator at the Institute for High Energy Physics. The required radiation flux density at the detector was produced by means of radioactive sources. The time resolution of 80 ps or better was attained at a rate of ∼20 kHz/cm(2) and an operating temperature of 45°C.

Total numbers of views: 1116
Numbers of unique views: 474
DOI: 10.1134/S002044121302005X
 Record created 2013-08-02, last modified 2014-01-30



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)