Published Article


ENERGY AND SPATIAL RESOLUTION OF THE HADRON STEEL-SCINTILLATOR TYPE CALORIMETER WITH 15-CM CELL


O.P. Gavrishchuk ; V.S. Datsko ; R.V. Eremeev ; M.G. Kadykov ; I.G. Kosarev ; V.V. Kukhtin ; D.V. Peshekhonov ; V.K. Semenov ; A.B. Shalygin
ПТЭ

Published in: Приборы и техника эксперимента
Vol.: 33    Num./Issue: 3
Page No: 33-36
ISSN: 0032-8162
Year: ПТЭ / 1991

Abstract: The procedure for determination of energy and spatial resolutions for the hodoscope hadron steel-scintillator type calorimeter consisting of 16 independent moduli is described. The data on measuring the hadron shower profile are given. The energy resolution &247;E=13.7% and spatial resolution σX=1.7 cm was obtained when detecting 37.5 GeV pions minus.


Language: rus

Total numbers of views: 906
Numbers of unique views: 397
 Record created 2011-05-25, last modified 2014-01-30



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)