/ General Physics arXiv:0906.4441


Development of detector active element based on THGEM


Inshakov, V. (Serpukhov, IHEP) ; Kryshkin, V. (Serpukhov, IHEP) ; Skvortsov, V. (Serpukhov, IHEP) ; Sytin, A. (Serpukhov, IHEP) ; Kuzmin, N. (Dubna, JINR) ; Sychkov, S. (Dubna, JINR)

Pages: 7

Abstract: A thick gas electron multiplier is considered for radiation-hard detectors (hadron calorimeter). There was carried out technological and design study to optimize the element structure. The measurements results and the next plans are presented.

Total numbers of views: 485
Numbers of unique views: 239
 Запись создана 2010-10-29, последняя модификация 2014-01-30



Оценить этот документ:

Rate this document:
1
2
3
 
(Еще не рецензированная)